It's the season of Willow Catkins flying all over the sky again, so the users in the air compressor industry have to get busy, they have to observe and regularly clean the radiator of the air compressor, so as not to block up and cause a high temperature shutdown。
The cleaning method is as follows: First, the air compressor tank to fill, and then stop, and then open the machine outside baffle, from the tank connected to a gas line, blowing toward the radiator, blowing from the top down (single hole single hole) , blow several times repeatedly (half an hour is the best) , and then the air compressor inside the dust, particles blowing clean up, and with the window screen up! Prevent the fan from being sucked into the radiator again causing blockage, again cause high temperature. If the radiator has not been cleaned for a long time, or the machine is used in bad conditions, the radiator surface is covered with oil or paint, the above method is not clean, the only solution is to remove the radiator from the air compressor, clean it with a special cleaning agent。